What was found
CORROSION ON STR 27R AT STA 360. FABRICATED STR SPLICE, LOCATED, ALODINED, PRIMED AND INSTALLED STR SPLICE IAW B727 DRAWING 65-18420, B727 SRM 51-10-2 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON STR 27R AT STA 360. FABRICATED STR SPLICE, LOCATED, ALODINED, PRIMED AND INSTALLED STR SPLICE IAW B727 DRAWING 65-18420, B727 SRM 51-10-2 AND 51-30-2.