What was found
DURING ROUTINE C-CHECK INSPECTION FOUND GOUGE AT STRINGER 25L BS 400. FABRICATED AND INSTALLED REPAIR DOUBLERS AT BS 400 STR 25L, ALODINED AND PRIMED IAW SRM 53-10-1, 53-10-2, 53-10-3 FIG 2, 51-10-2, 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE C-CHECK INSPECTION FOUND GOUGE AT STRINGER 25L BS 400. FABRICATED AND INSTALLED REPAIR DOUBLERS AT BS 400 STR 25L, ALODINED AND PRIMED IAW SRM 53-10-1, 53-10-2, 53-10-3 FIG 2, 51-10-2, 51-30-2.