What was found
DURING ROUTINE C-CHECK INSPECTION FOUND GOUGE AT MAIN CABIN FLOORBEAM BS 950 AT RBL 7. FABRICATED AND INSTALLED ANGLES, FILLER AND FLOORBEAM T-CAP AT BS 950 RBL 45 TO LBL 45, ALODINED AND PRIMED IAW SRM 53-10-2, 51-10-2, 53-10-8 FIG 8, 51-30-2.