What was found
DURING ROUTINE C-CHECK INSPECTION FOUND CRACK AT FORWARD CARGO COMPARTMENT, LOWER LOBE, STRINGER 26L EITHER SIDE OF BS 540 FRAME. STOP DRILLED, FABRICATED AND INSTALLED REPAIR ANGLE, ALODINED AND PRIMED IAW SRM 51-10-1, 53-10-3, 51-10-2, 51-30-2.