What was found
LT FUSELAGE CREASE BEAM WEB IS CRACKED AT BS 1090 FLOOR LEVEL. CUT OUT CRACKED AREA. FABRICATED AND INSTALLED WEB AND FILLER ANGLE. REPAIRS IAW B727 SRM 51-30-2, 51-10-1, 51-40-2, 51-10-2 AND MM 51-22-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT FUSELAGE CREASE BEAM WEB IS CRACKED AT BS 1090 FLOOR LEVEL. CUT OUT CRACKED AREA. FABRICATED AND INSTALLED WEB AND FILLER ANGLE. REPAIRS IAW B727 SRM 51-30-2, 51-10-1, 51-40-2, 51-10-2 AND MM 51-22-11.