What was found
UPON A SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, THE AFT BULKHEAD CENTER PANEL, FORWARD CARGO PIT HAS CRACKED AND TORN FASTENER HOLES IN BOTTOM END OF PANEL. DRESSED OUT CRACKED AND TORN AREA. FABRICATED AND INSTALLED TWO DOUBLERS IAW B727 SRM 51-40-2. (M)