What was found
UPON A SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, CORROSION WAS FOUND ON THE MOUNT FITTING AT INBOARD END OF NR 2 LEADING FLAP. REMOVED NR 2 KRUGER FLAP. REMOVED AND REPLACED MOUNT FITTING. REPLACED ATTACH ANGLE AND REINSTALLED NR 2 KRUGER FLAP IAW B727 MM 27-8-1 SRM 51-40-3 AND 51-30-2. (M)