What was found
DURING SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, FOUND LEFT MAIN LANDING GEAR, FORWARD TRUNNION ACCESS PANEL AROUND MOUNTING HOLES. REMOVED DAMAGED AREA IAW B727 SRM 53-30-3. FAB NEW REPAIR IAW SRM B727 53-30-3. PRIMED AND ALODINED REPAIR IAW SRM B727 53-10-2. INSTALLED NEW REPAIR IAW SRM B727 53-30-3. (M)