What was found
DURING SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, EXCESSIVE METAL REMOVED FROM NR 4 SLAT SKIN NEXT TO TELESCOPING DUCT PANEL SEAL. FABRICATED REPAIR IAW SRM 57-30-3, ALODINED IAW SRM 51-10-2, SEALED REPAIR IAW SRM 57-30-5. INSTALLED REPAIR IAW SRM 57-30-3. REPAIR DOUBLER FABRICATED FROM 2024-T3-0.080 APPROX 6 INCHES BY 3.5 INCHES. (M)