What was found
DURING SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, CORROSION BEYOND LIMITS NR 2 SLAT ATTACH ANGLE IAW 51-10-6 100 PERCENT METAL REMOVAL WAS FOUND. FABRICATED NEW ATTACH ANGLE, ALODINED AND PRIMED AND INSTALLED NEW BRACKET IAW B727 SRM 51-10-1, 51-10-2, 51-40-3 L-ANGLE 7075T6 .063 5.2187 BY 1.5 BY .75 INCH. (M)