What was found
AN .75 INCH CRACK INDICATION, STRINGER 3L BS 1080. HFEL CONFIRMED CRACK LOCATED STRINGER 4L STATION 1072. REPAIRED PER SRM 53-30-3 AND SB 727-53-0072 AND AD 91-06-06. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AN .75 INCH CRACK INDICATION, STRINGER 3L BS 1080. HFEL CONFIRMED CRACK LOCATED STRINGER 4L STATION 1072. REPAIRED PER SRM 53-30-3 AND SB 727-53-0072 AND AD 91-06-06. (M)