What was found
HFEC INSPECTION INDICATES CRACKS IN FWD 2 FASTENER HOLES STATION 760, LT. STOP DRILLED CRACKS, HFEC VERIFIES CRACKS CONTAINED. INSTALLED REPAIR PER BOEING DRAWING 65C 33202 AND SB 57-112. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HFEC INSPECTION INDICATES CRACKS IN FWD 2 FASTENER HOLES STATION 760, LT. STOP DRILLED CRACKS, HFEC VERIFIES CRACKS CONTAINED. INSTALLED REPAIR PER BOEING DRAWING 65C 33202 AND SB 57-112. (M)