What was found
STRAP PLATE IS BROKEN 2ND FROM LEFT UNDER BEAM STATION 344 AND BEAM STATION 360. FORWARD CABIN UNDER FLOOR. FABRICATE NEW PLATE PER SRM 51-10-1. INSTALLED PLATE AND FASTENERS PER SRM 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRAP PLATE IS BROKEN 2ND FROM LEFT UNDER BEAM STATION 344 AND BEAM STATION 360. FORWARD CABIN UNDER FLOOR. FABRICATE NEW PLATE PER SRM 51-10-1. INSTALLED PLATE AND FASTENERS PER SRM 51-30-2. (M)