What was found
DURING HIGH FREQUENCY EDDY CURRENT INSPECTION FOR CRACKS AT DENT LOCATION, FOUND CRACK JUST BELOW DENT AT LIGHTNING STRIKE AT FS 260 AND LONGERON 19L. CUT OUT, FABRICATED DOUBLERS AND INSTALLED PER SRM 53-04 FIGURE 38. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HIGH FREQUENCY EDDY CURRENT INSPECTION FOR CRACKS AT DENT LOCATION, FOUND CRACK JUST BELOW DENT AT LIGHTNING STRIKE AT FS 260 AND LONGERON 19L. CUT OUT, FABRICATED DOUBLERS AND INSTALLED PER SRM 53-04 FIGURE 38. (M)