What was found
DURING ACCOMPLISHMENT OF CPCP CARD C53-224-01 REVEALED CORROSION ON FLOORBEAM AT FS 400 LBL 45. TRIMMED DAMAGED UPPER CHORD. FABRICATED AND INSTALLED REPAIR PER SRM 53-10-8 FIGURE 3 AND 51-30-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ACCOMPLISHMENT OF CPCP CARD C53-224-01 REVEALED CORROSION ON FLOORBEAM AT FS 400 LBL 45. TRIMMED DAMAGED UPPER CHORD. FABRICATED AND INSTALLED REPAIR PER SRM 53-10-8 FIGURE 3 AND 51-30-02. (M)