What was found
DURING ACCOMPLISHMENT OF A ROUTINE C-CHECK WORK CARD, FOUND CLIP CRACKED AT FS 700 STRINGER 20L. FABRICATED NEW CLIP PER SAMPLE, TREATED AND PRIMED PER SRM 51-10-2 AND MM 51-20-2. INSTALLED NEW CLIP PER SRM 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ACCOMPLISHMENT OF A ROUTINE C-CHECK WORK CARD, FOUND CLIP CRACKED AT FS 700 STRINGER 20L. FABRICATED NEW CLIP PER SAMPLE, TREATED AND PRIMED PER SRM 51-10-2 AND MM 51-20-2. INSTALLED NEW CLIP PER SRM 51-30-2. (M)