What was found
M/R BLADE SEPARATION BETWEEN TIP RIB AND BLADE ASSY. INSPECTED, PERFORMED X RAY, ULTRASONIC INSPECTIONS PER QATI3048-3016, SS8806 & 6095, PERFORMED ALL INSPECTIONS UP TO AND INCLUDING 900 HOUR INSPECTIONS CMPLIED WITH AD 84-10-02, ASB 76-65-18C &N ASB 76-65-57. REPLACED SHIMS PER SA4047-76-5 PROCEDURE NO 9 REV 9 REPLACED 4 ROOT END THROUGH BUSHINGS PER RS-004N-VII; REPLACED STIFFNERS PER RS-003C; REPAIRED VOID ON UPPER SURFACE AT TIP PER PROCEDURE NR 18-1PLY; REPLACED NICKEL STRIP PER RS-007J-I; INJECTED SHEATH VOID AT TIP PER SA4047-76-5 PROCEDURE 2; REINSTALLED TIP CAP SN A175-03746; REFINISHED PAINT WITH HIGH VIS SCHEME 02 PER S76 SRM SA4047-76-5 DRWG 76150-09000 AND 76150-09100; STATIC BALANCED PER CTI-DAL-