What was found
UNABLE TO TRACK, DIVES OVER 40 KNOTS WITH ANY ADJUSTMENT. SENT FOR REPAIR. INSPECTED, PERFORMED 2500 HOUR INSPECTIONS IAW BHT-412-MM CHAPTER 5: XRAY INSPECTION OF TRAILING EDGE CORE IN AREA OF OB TRIM TAB REVEALS APPROX 50-75 CELLS OF MOISTURE INGRESSION IAW ASTM E 94; MOISTURE REMOVED; REPLACED OB AND CENTER TRIM TABS IAW 204-099-223 APPENDIX B SECTION 2 PARAGRAPH 2.7 REV L; REPAIRED SKIN DAMAGE ON UPPER SURFACE AT STA 194.125 TO STA 195.250 INCLUDING DAMAGE UNDER TRIM TAB IAW DAL-637 AND 8110-26727; REPLACED IB SPLICE COVER IAW BHT 412 CR AND O PAGE 86B; REMOVED AND REINSTALLED TIP CAP IAW 8110-38493 AND CTI PROCEDURE 412-62-10-800.