What was found
UNIT HAS LOW PRESSURE, BARE METAL SHOWING, ID PLATE IS DAMAGED, WARNING LABEL IS DAMAGED, PRESSURE GUAGE IS 50 PSI OUT OF CALIBRATION. ACTION TAKEN: CLEANED, INSEPCTED, HYDROTESTED IAW CFR 49 180.205, BEAD BLAST AND PAINTED, OVERHAULED, REPLACED GUAGE, INSTALLED DECALS, FILLED, LEAK CHECKED, WT CHECKED (7.00 LBS W/ CARTRIDGES INSTALLED) IAW CMM 26-21-83 REV 4