What was found
EMEGENCY LIGHTS INOPERATIVE AT SIDE KICK PANELS AT ALL EMERGENCY EXITS. R & R NR 3 POWER SUPPLY UNIT AS REQUIRED WITH AN INSPECTED UNIT. OPS CHECKED GOOD. WORK DONE IAW MM SECTION 33-51-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMEGENCY LIGHTS INOPERATIVE AT SIDE KICK PANELS AT ALL EMERGENCY EXITS. R & R NR 3 POWER SUPPLY UNIT AS REQUIRED WITH AN INSPECTED UNIT. OPS CHECKED GOOD. WORK DONE IAW MM SECTION 33-51-00.