What was found
CAPT REORTED :FIRE WARNING INTERMITTEM,ACRAS DOWNLINK MSG:NO.1 ENG N2 VIB 5.0,EGT 2022,A/C AIR RETURN TO ANC. MAINTENANCE GOUND INSPECTION,1.FOUND NO.1 ENG TAIL PIPE BROKEN, N1 SIEZED, BIG CHIP FOUND AND TWO FIRE BOTTLES DISCHARGED. 2.NO.1 ENG LEVER ARM STG #5 BLADES BROKEN, 2 BLOW OUT DOOR OPENED AND PNEUM DUCT LINK B BROKEN. REPLACED NO.1 ENG AND FOUND ALL COND ARE NML.