As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT AFT STIFFENER IN CENTER POST HAS A 2 INCH CRACK ACROSS THE STIFFENER APPROXIMATELY AT WATERLINE 67, RIGHT BL 5 AND STATION 82. RT WEB HAS 1 INCH CRACK IN SAME LOCATION. REMOVED AND REPLACED RT AFT BROOM CLOSET ANGLE P/N 206-033-110-239S AND REPAIRED CRACK R/H BROOM CLOSET SKIN IAW SRM. NO DEFECTS NOTED