What was found
DEN - DURING C-7 CHECK INSPECTION, REPORTED FUSELAGE FRAME CRACKED ON TOP FLANGE AND RADIUS AT STATION 727B, STRINGER 23R, IN AFT CARGO PIT. MAINTENANCE REMOVED DAMAGED SECTION OF FRAME, FABRICATED REPAIR DOUBLER PER EO 51-00-737-001, AND INSTALLED REPAIR DOUBLER PER SRM 51-70-11 AND 51-40-02. (M)