What was found
DEN - DURING C-7 CHECK INSPECTION REPORTED INTERCOSTAL CORRODED AT FORWARD SIDE OF FLOORBEAM 312, BL 0. MAINTENANCE REMOVED DAMAGED AREA. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER EA 53-737-068 AND SRM 51-20-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DEN - DURING C-7 CHECK INSPECTION REPORTED INTERCOSTAL CORRODED AT FORWARD SIDE OF FLOORBEAM 312, BL 0. MAINTENANCE REMOVED DAMAGED AREA. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER EA 53-737-068 AND SRM 51-20-01. (M)