What was found
DURING C-7 INSPECTION, FOUND FRAME CRACKED IN RADIUS FORWARD OF E/E BAY DOOR AT BS 294.5, STRINGER 23R. MAINTENANCE REMOVED DAMAGED SHEAR TIE, FABRICATED AND INSTALLED REPLACEMENT SHEAR TIE PER SRM 53-10-4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-7 INSPECTION, FOUND FRAME CRACKED IN RADIUS FORWARD OF E/E BAY DOOR AT BS 294.5, STRINGER 23R. MAINTENANCE REMOVED DAMAGED SHEAR TIE, FABRICATED AND INSTALLED REPLACEMENT SHEAR TIE PER SRM 53-10-4. (M)