DEN - DURING C-7 CHECK, INSPECTION REPORTED BARE METAL AND SURFACE CORROSION ON FLOORBEAM NEAR CENTER OF FLOOR AT BS 950. MAINTENANCE BURNISHED SURFACE CORROSION AND REPLACED INTERCOSTAL BETWEEN BS 950 AND BS 966, LBL 8 PER SRM 53-10-09. (M)