What was found
DEN - DURING C-7 CHECK, INSPECTION REPORTED CORROSION ON FLOOR FRAME CENTER INTERCOSTAL AT BS 927 TO BS 947. MAINTENANCE FABRICATED REPLACEMENT WEB SECTION PER EA 53-737-047 AND SRM 51-30-2 AND INSTALLED NEW SECTION PER SRM 51-30-2 AND EA 53-737-071. (X)