What was found
DEN - DURING C-7 CHECK INSPECTION, REPORTED NR 2 ENGINE EXHAUST CASE CRACKED AT 3, 6 AND 9 O''CLOCK STRUTS AT ROOT OF FAIRING, AND OUTBOARD LEADING EDGE OR 9:00 O''CLOCK STRUT. MAINTENANCE REPLACED NR 2 ENGINE PER WORK CARD 7-0316. (M)