What was found
DEN - DURNG C-2 CHECK INSPECTION, FOUND FLOOR ANGLE CRACKED AT CENTER OF FLOOR, BS 360-380, FLOOR CAP SECTION. MAINTENANCE REMOVED CRACKED ANGLE. FABRICATED AND INSTALLED REPLACEMENT SHEAR WEB TOP ANGLE PER SRM 53-30-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DEN - DURNG C-2 CHECK INSPECTION, FOUND FLOOR ANGLE CRACKED AT CENTER OF FLOOR, BS 360-380, FLOOR CAP SECTION. MAINTENANCE REMOVED CRACKED ANGLE. FABRICATED AND INSTALLED REPLACEMENT SHEAR WEB TOP ANGLE PER SRM 53-30-51. (M)