What was found
DEN - FOUND DURING C-2 CHECK INSPECTION, AFT FLOOR SUPPORT CORRODED STATION 986.5 TO 1006 BL0. MAINTENANCE REMOVED DAMAGED AREA, FABRICATED REPLACEMENT INTERCOSTAL AND INSTALLED PER EA 53-737-082. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DEN - FOUND DURING C-2 CHECK INSPECTION, AFT FLOOR SUPPORT CORRODED STATION 986.5 TO 1006 BL0. MAINTENANCE REMOVED DAMAGED AREA, FABRICATED REPLACEMENT INTERCOSTAL AND INSTALLED PER EA 53-737-082. (M)