What was found
DEN - DURING C-3 CHECK INSPECTION REPORTED CORROSION IN CLIP NUT HOLES OF INTERCOSTAL, STATION 294.5 TO 312, BL 12L, FORWARD CABIN FLOOR STRUCTURE. MAINTENANCE REMOVED DAMAGED INTERCOSTAL. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER SRM 51-30-00. (M)