What was found
DEN - FOUND DURING C-2 CHECK, CORROSION ON TOP OF FLOORBEAM CENTER AT STATION 292.5, LBL 5. MAINTENANCE REPLACED FLOORBEAM UPPER CHORD PER SRM''S 51-10-02, 51-30-02, 53-10-01 AND 53-10-09. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DEN - FOUND DURING C-2 CHECK, CORROSION ON TOP OF FLOORBEAM CENTER AT STATION 292.5, LBL 5. MAINTENANCE REPLACED FLOORBEAM UPPER CHORD PER SRM''S 51-10-02, 51-30-02, 53-10-01 AND 53-10-09. (M)