What was found
DEN - DURING C-3 CHECK INSPECTION, FOUND CRACK IN FORWARD PRESSURE BULKHEAD HORIZONTAL WEB AT STATION 178, WL 195, RBL 20. MAINTENANCE FABRICATED AND INSTALLED HORIZONTAL WEB PER EO 53-10-737-014 AND SRM 53-10-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DEN - DURING C-3 CHECK INSPECTION, FOUND CRACK IN FORWARD PRESSURE BULKHEAD HORIZONTAL WEB AT STATION 178, WL 195, RBL 20. MAINTENANCE FABRICATED AND INSTALLED HORIZONTAL WEB PER EO 53-10-737-014 AND SRM 53-10-11. (M)