What was found
DEN - DURING C-3 CHECK, FOUND NR 2 ENGINE INLET TRAILING EDGE MATING SURFACE FOR ENGINE COWL AT 6:00 POSITION WORN VERY THIN. MAINTENANCE REMOVED DAMAGED AREA, FABRICATED TWO REPAIR ANGLES AND FILLERS PER SRM 54-10-03 AND TREATED AND PRIMED PER SRM 51-10-02. INSTALLED PER SRM 54-10-03. (M)