What was found
DEN - DURING C-3 CHECK INSPECTION, REPORTED FLOOR TRACK CORRODED, STATION 344, BL 22L. MAINTENANCE REMOVED CORRODED SECTION OF TRACK AND FABRICATED AND INSTALLED REPLACEMENT TRACK PER SRM 51-30. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DEN - DURING C-3 CHECK INSPECTION, REPORTED FLOOR TRACK CORRODED, STATION 344, BL 22L. MAINTENANCE REMOVED CORRODED SECTION OF TRACK AND FABRICATED AND INSTALLED REPLACEMENT TRACK PER SRM 51-30. (M)