What was found
DURING C-7 CHECK, INSPECTION REPORTED CORROSION ON SHEAR TIE AT STA 500A BETWEEN STR 27L AND 26L. FABRICATED AND INSTALLED REPLACEMENT SHEAR TIE PER SRM 53-10-2, SRM 53-10-4, SRM 51-30-2 AND SOPM 20-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-7 CHECK, INSPECTION REPORTED CORROSION ON SHEAR TIE AT STA 500A BETWEEN STR 27L AND 26L. FABRICATED AND INSTALLED REPLACEMENT SHEAR TIE PER SRM 53-10-2, SRM 53-10-4, SRM 51-30-2 AND SOPM 20-41-02.