What was found
DURING C-6 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM UPPER TEE CHORD AT STA 1016, LBL 33. CLEANED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-00-51. FABRICATED AND INSTALLED REPAIR PER SRM 53-00-51, 51-40-02 AND SOPM 20-41-02.