What was found
DURING C-6 CHECK, INSPECTION REPORTED CORROSION ON VERTICAL FLANGE OF BS 794.3 FRAME, BETWEEN STR 24-R AND 26-R. INSTALLED REPLACEMENT FRAME PER SRM 51-40-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-6 CHECK, INSPECTION REPORTED CORROSION ON VERTICAL FLANGE OF BS 794.3 FRAME, BETWEEN STR 24-R AND 26-R. INSTALLED REPLACEMENT FRAME PER SRM 51-40-2.