What was found
DURING C-6 CHECK, INSPECTION REPORTED CARGO FLOOR TRACK CORRODED AT BS 800 TO 840 ABOVE STR 26R IN AFT CARGO BAY. FABRICATED FLOOR TRACK AND SPLICE PLATES AND INSTALLED PER SRM 53-00-53, 51-10-02, SEC 53, AND SOPM 20-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-6 CHECK, INSPECTION REPORTED CARGO FLOOR TRACK CORRODED AT BS 800 TO 840 ABOVE STR 26R IN AFT CARGO BAY. FABRICATED FLOOR TRACK AND SPLICE PLATES AND INSTALLED PER SRM 53-00-53, 51-10-02, SEC 53, AND SOPM 20-41-02.