What was found
DURING C-7 CHECK, INSPECTION REPORTED INTERCOSTAL CRACKED AT STR 26-L, STA 460. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER SRM 53-10-2 AND 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-7 CHECK, INSPECTION REPORTED INTERCOSTAL CRACKED AT STR 26-L, STA 460. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER SRM 53-10-2 AND 51-10-02.