What was found
DURING C-7 CHECK, INSPECTION REPORTED INTERCOSTAL BENT AND CRACKED AT STA 500, STR 26-L. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER SRM 51-10-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-7 CHECK, INSPECTION REPORTED INTERCOSTAL BENT AND CRACKED AT STA 500, STR 26-L. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER SRM 51-10-1.