What was found
DURING C-7 CHECK, INSPECTION REPORTED INTERCOSTAL CRACKED AT STA 440, STR 26-L. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER SRM 51-30-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-7 CHECK, INSPECTION REPORTED INTERCOSTAL CRACKED AT STA 440, STR 26-L. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER SRM 51-30-1.