What was found
DURING C-3 CHECK, INSPECTION REPORTED TRANSITION PANEL AT STA 520, STR 26-L, CORRODED AT NUT PLATE LOCATION. FABRICATED AND INSTALLED REPLACEMENT PANEL PER SRM 51-10-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-3 CHECK, INSPECTION REPORTED TRANSITION PANEL AT STA 520, STR 26-L, CORRODED AT NUT PLATE LOCATION. FABRICATED AND INSTALLED REPLACEMENT PANEL PER SRM 51-10-1.