What was found
DURING C-3 CHECK, INSPECTION REPORTED INTERCOSTALS BETWEEN STA 787 AND 794, STR 16R TO 26R, CORRODED. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTALS PER SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-3 CHECK, INSPECTION REPORTED INTERCOSTALS BETWEEN STA 787 AND 794, STR 16R TO 26R, CORRODED. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTALS PER SRM 51-30-2.