What was found
DURING C-3 CHECK, INSPECTION REPORTED WEB AT STA 996 TO STA 1016, RBL 40, NEXT TO R2 DOOR CORRODED. FABRICATED AND INSTALLED REPLACEMENT WEB PER SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-3 CHECK, INSPECTION REPORTED WEB AT STA 996 TO STA 1016, RBL 40, NEXT TO R2 DOOR CORRODED. FABRICATED AND INSTALLED REPLACEMENT WEB PER SRM 51-30-2.