As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-3 CHECK, INSPECTION REPORTED CORROSION AROUND EDGES OF AFT FLOOR PANEL IN FWD CARGO COMPARTMENT. REMOVED CORROSION AROUND EDGES OF AFT FLOOR PANEL PER SRM 51-10-06. FABRICATED AND INSTALLED REPLACEMENT RETAINER STRAP PER SRM 51-10-01, 51-10-02 AND SOPM 20-41-02.