What was found
DURING C4 CHECK, INSPECTION REPORTED ELONGATED HOLE ON INTERCOSTAL AT BS 500A-500B, STR 26. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER SRM 51-10-02, 51-50-02 AND SOPM 20-41-01.