What was found
DURING C-4 CHECK, INSPECTION REPORTED AFT CARGO COMPARTMENT FLOOR SPLICE PANEL AT BS 771 CORRODED. FABRICATED AND INSTALLED REPLACEMENT PARTS PER SRM 51-10-01 AND 51-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-4 CHECK, INSPECTION REPORTED AFT CARGO COMPARTMENT FLOOR SPLICE PANEL AT BS 771 CORRODED. FABRICATED AND INSTALLED REPLACEMENT PARTS PER SRM 51-10-01 AND 51-20-01.