What was found
DURING C 4 CHECK, CORROSION WAS FOUND ON FLOOR SUPPORT LOCATED AT LBL 29, BETWEEN STA 986.5 AND STA 1006. NEW FLOOR SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 53-60-51, SOPM 26-41-02 AND SRM 51-40 02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C 4 CHECK, CORROSION WAS FOUND ON FLOOR SUPPORT LOCATED AT LBL 29, BETWEEN STA 986.5 AND STA 1006. NEW FLOOR SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 53-60-51, SOPM 26-41-02 AND SRM 51-40 02.