What was found
DURING C 6 CHECK, INSPECTION FOUND CORROSION IN THE AFT CARGO PIT FLOOR SUPPORT ANGLE AT STATION 750 TO 754. REPAIR WAS PERFOMED BETWEEN STA 767 AND 787 AND FOUND TO BE WITHIN THE LIMITS ESTABLISHED IN SRM 53-60-15, FIGURE 101, DETAIL V. THE PART WAS TREATED, PRIMED AND PAINTED IN ACCORDANCE WITH SOPM 20-41-02